| International Greenhouse Company Inc. |
|
|
|
|
| 203 Market
Street - Sidell, IL 61876 USA |
|
|
| Phone: 1-888-281-9337 Fax: 1-217-288-9084 |
|
|
| e-mail: CustomerService@igcusa.com |
|
|
|
| WebSite: http://www.igcusa.com |
|
|
|
|
| CUSTOMER |
RON'S FLORAL |
|
QUOTE |
3457 |
|
| ATT: |
|
RON EDWARD |
|
DATE |
11/22/2000 |
|
| ADDRESS |
320 MAIN |
|
|
|
| CITY |
|
SIDELL |
|
|
|
|
|
| STATE |
|
IL |
|
ZIP |
61876 |
COUNTRY |
USA |
|
| PHONE |
|
217-288-0753 |
FAX |
217-288-0884 |
|
|
|
| E-MAIL |
|
ronsfloral@unet.net |
|
|
|
| We are pleased to
quote on the following greenhouse system: |
|
|
| |
|
|
|
|
|
|
|
|
|
|
| STRUCTURAL STEEL
FRAME: |
|
|
|
|
|
QUANTITY |
|
UNIT |
|
DESCRIPTION |
|
|
|
|
|
3 |
|
EA. |
|
GUTTER CONNECTED |
GALVANIZED STEEL |
|
|
CONLEY GREENHOUSE FRAME |
|
GABLE 7500 |
|
|
HOUSE WIDTH: |
30 |
FT. |
|
|
HOUSE LENGTH: |
108 |
FT. |
|
|
SIDEWALL HEIGHT: |
10 |
FT. |
|
|
ROOF LOAD: |
20 |
LBS./SQ.FT. |
|
|
TOTAL AREA: |
9,720 |
SQ. FT. |
|
|
1 |
|
EA. |
|
MAN DOOR |
|
|
|
|
2 |
|
EA. |
|
SLIDING DOOR |
|
|
|
0 |
|
EA. |
|
INTERIOR PARTITION WALL W/ GLAZING |
|
|
|
|
| GLAZING: |
|
|
|
|
|
QUANTITY |
|
UNIT |
|
DESCRIPTION |
|
|
|
|
|
11,411 |
|
SQ. FT. |
|
8mm POLYCARB |
ROOF COVERING |
|
|
1,134 |
|
SQ. FT. |
|
8mm POLYCARB |
SIDE WALL COVERING |
|
|
1,134 |
|
SQ. FT. |
|
8mm POLYCARB |
OPP. SIDE WALL COVERING |
|
|
1,969 |
|
SQ. FT. |
|
8mm POLYCARB |
END WALL COVERING |
|
|
1,969 |
|
SQ. FT. |
|
8mm POLYCARB |
OPP. END WALL COVERING |
|
|
0 |
|
EA. |
|
INFLATION FANS |
|
|
|
|
| VENTILATION SYSTEM: |
|
|
|
|
|
QUANTITY |
|
UNIT |
|
DESCRIPTION |
|
|
|
324 |
|
L.F. |
|
ROOF VENT |
SINGLE |
|
|
|
216 |
|
L.F. |
|
SIDE OR END VENT |
|
|
0 |
|
EA. |
|
FAN JET |
MODEL NO. |
0 |
|
|
0 |
|
EA. |
|
FAN JET SHUTTER, MOTORIZED |
|
|
|
0 |
|
EA. |
|
FAN JET TUBE W/ HANGERS |
|
|
0 |
|
EA. |
|
FAN JET HEAT KIT |
|
|
|
6 |
|
EA. |
|
HAF FAN (2000 CFM) |
|
|
|
0 |
|
L.F. |
|
POLYVENT SYSTEM |
W/ INFLATION FAN |
|
|
0 |
|
L.F. |
|
DROP CURTAIN |
W/ MANUAL WINCH |
|
|
| COOLING SYSTEM: |
|
|
|
|
|
QUANTITY |
|
UNIT |
|
DESCRIPTION |
|
|
|
|
|
6 |
|
EA. |
|
COOLAIR EXHAUST FAN |
|
NBF36K |
|
|
|
W/ SLANT
WALL HOUSING, SHUTTERS & GUARDS |
|
|
90 |
|
L.F. |
|
EVAP. COOL SYSTEM |
ALUM |
PAD HEIGHT= |
3 |
|
1 |
|
EA. |
|
SUMP PUMP & PIPING |
|
|
|
1 |
|
EA. |
|
SUMP TANK |
|
|
|
0 |
|
EA. |
|
INLET SHUTTER W/ MOTOR |
0 |
|
|
90 |
|
L.F. |
|
PAD VENT |
|
|
|
1 |
|
EA. |
|
INLET VENT MOTOR & CONTROLLER |
|
|
|
|
|
NOTE:
COOLING SYSTEM DESIGNED FOR FOLLOWING CONDITIONS: |
|
|
|
MAX. INTERIOR FOOT CANDLES |
|
5,000 |
|
|
|
MAX. PAD TO FAN TEMP. VARIATION |
|
7 |
|
|
|
MAX. SUMMER OUTDOOR W.B. TEMPERATURE |
75 |
|
|
|
MAX. SUMMER OUTDOOR D.B. TEMPERATURE |
95 |
|
|
|
MAX. SUMMER INDOOR D.B. TEMPERATURE |
86 |
|
|
|
TOTAL CFM AT |
850 |
FT. ABOVE SEA LEVEL |
78,630 |
|
|
|
|
| HEATING: |
|
|
|
|
|
QUANTITY |
|
UNIT |
|
DESCRIPTION |
|
|
|
|
|
3 |
|
EA. |
|
UNIT HEATER |
HE GAS |
|
|
|
MODINE MODEL |
PV300 |
|
|
|
0 |
|
EA. |
|
POLYTUBE AIR DUCT W/ HANGERS |
|
|
|
|
|
NOTE:
HEATING SYSTEM DESIGNED FOR THE FOLLOWING CONDITIONS: |
|
|
|
MINIMUM
INSIDE TEMP. |
|
65 |
DEGREES F. |
|
|
|
MINIMUM
OUTSIDE TEMP. |
-10 |
DEGREES F. |
|
|
|
HEAT
LOSS |
850 |
FT. ELEV. |
679,551 |
BTUH |
|
|
|
|
| CONTROL SYSTEM: |
|
|
|
|
|
QUANTITY |
|
UNIT |
|
DESCRIPTION |
|
|
|
|
|
1 |
|
EA. |
|
MICRO-GROW CONTROLLER |
|
|
|
3
STAGE COOL, 2 STAGE HEAT |
|
|
|
1 |
|
EA. |
|
VENT CONTROL, MASTER |
|
|
|
4 |
|
EA. |
|
VENT CONTROL, SLAVE |
|
|
|
0 |
|
EA. |
|
VENT CONTROL, MANUAL |
|
|
|
| GROW LIGHT SYSTEM: |
|
|
|
|
|
QUANTITY |
|
UNIT |
|
DESCRIPTION |
|
|
|
|
|
77 |
|
EA. |
|
HPS LIGHT, FIXTURE & 400 W. BULB |
|
|
|
W/ MOUNTING TRACK & CORD |
|
|
|
FOOT CANDLES = |
300 |
|
|
0 |
|
EA. |
|
LIGHTING CONTROLLER |
|
|
|
| IRRIGATION SYSTEM: |
|
|
|
|
|
QUANTITY |
|
UNIT |
|
DESCRIPTION |
|
|
|
|
|
1 |
|
EA. |
|
IRRIGATION SYSTEM |
|
|
|
|
|
|
| AUXILIARY SYSTEMS: |
|
|
|
|
|
QUANTITY |
|
UNIT |
|
DESCRIPTION |
|
|
|
|
|
5,000 |
|
SQ. FT. |
|
BENCH SYSTEM |
ROLLING |
|
|
|
9,720 |
|
SQ. FT. |
|
AUTO. ENERGY CURTAIN |
|
|
|
1 |
|
EA. |
|
FERTILIZER INJECTOR |
|
|
|
1 |
|
EA. |
|
GROUND HEATING SYSTEM |
|
|
|
|
| CONSTRUCTION: |
|
|
|
|
|
QUANTITY |
|
UNIT |
|
DESCRIPTION |
|
|
|
|
|
0 |
|
SQ. FT. |
|
CONCRETE SLAB |
|
|
|
|
116 |
|
CU. YD. |
|
4" GRAVEL |
|
|
|
|
300 |
|
SQ. FT. |
|
CONCRETE WALKWAY |
|
|
|
|
52 |
|
EA. |
|
DRILL COLUMN HOLE |
|
|
|
13 |
|
CU. YD. |
|
COLUMN CONCRETE |
|
|
|
|
0 |
|
SQ. FT. |
|
GROUND COVER |
|
|
|
|
1 |
|
SET |
|
CONSTRUCTION DRAWINGS |
|
|
|
0 |
|
EA. |
|
SITE PREPARATION (FINAL GRADING ONLY) |
|
|
1 |
|
EA. |
|
POUR FOUNDATION & SET COLUMNS |
|
|
|
1 |
|
EA. |
|
ERECT HOUSE & INSTALL EQUIPMENT |
|
|
|
1 |
|
EA. |
|
PROVIDE JOBSITE SUPERVISION |
|
|
|
1 |
|
EA. |
|
PROVIDE ELECTRICAL INSTALLATION |
|
|
|
1 |
|
EA. |
|
PROVIDE MECHANICAL INSTALLATION |
|
|
|
|
| PRICING SUBTOTALS: |
|
|
|
|
|
|
|
|
|
|
STRUCTURE |
|
|
$29,986
|
|
|
|
|
COVERING |
|
|
$23,005
|
|
|
|
|
SUBTOTAL
STRUCTURE |
|
$52,991
|
|
|
|
|
|
|
VENTILATION SYSTEM |
|
$8,757
|
|
|
|
|
COOLING SYSTEM |
|
|
$9,214
|
|
|
|
|
HEATING SYSTEM |
|
|
$3,866
|
|
|
|
|
CONTROL SYSTEM |
|
|
$5,195
|
|
|
|
|
HPS LIGHTING SYSTEM |
|
$15,853
|
|
|
|
|
IRRIGATION SYSTEM |
|
$2,206
|
|
|
|
|
BENCH SYSTEM |
|
|
$14,706
|
|
|
|
AUTO. ENERGY CURTAIN |
|
$18,296
|
|
|
|
FERTILIZER INJECTOR |
|
$441
|
|
|
|
GROUND HEATING SYSTEM |
|
$16,235
|
|
|
|
|
|
|
SUBTOTAL
SYSTEMS |
|
$94,770
|
|
|
|
|
|
ENGINEERED DRAWINGS |
|
$625 |
|
|
|
|
SITE PREPARATION |
|
|
$0 |
|
|
|
|
FOUNDATION AND FLOOR |
|
$5,719
|
|
|
|
|
ERECT HOUSE & INSTALL EQUIPMENT |
|
$58,485 |
|
|
|
|
JOB SITE SUPERVISION |
|
INCLUDED |
|
|
|
|
ELECTRICAL INSTALLATION |
|
$9,720 |
|
|
|
|
MECHANICAL INSTALLATION |
|
$1,253 |
|
|
|
|
SUBTOTAL LABOR
& ERECT |
|
$75,802
|
|
|
|
|
|
|
FREIGHT
CHARGES |
|
$6,280 |
|
|
|
|
|
NET TOTAL |
|
|
$229,843 |
|
|
|
|
|
|
|
|
|
|
|
| Note: |
|
|
|
| Prices do not
include sales tax or permits. Prices
good for 30 days from date of quote. |
|
|
| Freight terms are
FFA to Jobsite. Freight will be
shipped prepaid. |
|
|
| Payment Terms are
50% Cash with order and balance upon delivery of merchandise. |
|
|
| For International
orders Payment Terms are 100% Irrevocable Letter of Credit. |
|
|
| Pricing may differ
if order is for different quantities than quoted. |
|
|
|
|
| Proposed by: |
|
Accepted by: |
|
|
|
|
|
|
|
|
|
| ____________________________________ |
_____________________________________ |
|
| DAVID GEORGE |
|
|
|
| INTERNATIONAL
GREENHOUSE COMPANY INC. |
RON'S FLORAL |
|
|
|
|
|
|
|
|
|
|
|